Xiamen AIR-ERV Technology Co., Ltd.
Main products:KRV,HRV,HEV,ERA,ERC
Products
Contact Us
  • Contact Person : Ms. Cai Eunice
  • Company Name : Xiamen AIR-ERV Technology Co., Ltd.
  • Tel : 86-592-5769019,1526 0209 436
  • Fax : 86-592-5769020
  • Address : Fujian,Xiamen,No.21,Siming Industrial Park,Meixi Road,Tongan District,Xiamen,China
  • Country/Region : China
  • Zip : 361100

ac heat exchanger for outdoor cabinet

ac heat exchanger for outdoor cabinet
Product Detailed
1.Cooling capacity:100 W/K 2.Air volume:500 m3//h 3.Demension:1200*440*188 mm 4.Noise:<60 Db(A) 5.Weight: 31 kg

 

Product Introduction

The outdoor cabinet/base station cooling heat exchanger is specifically designed for the cabinet and base station. Make use of temperature difference inside and outside of cabinet, exchange the heat through the heat exchanger core, be realized on the temperature adjustment, so as to satisfied the heat dissipation.Perfectly achieve high efficiency operation through the usage of nature cooling technology.It is much more reliable,much more cheaper comparing with air-conditioner 

solution.Indoor air and outdoor air are isolated perfectly, eliminate the dust contamination issue caused by ventilation, with low noise and safety.The heat exchanger core is made of aluminium foil, with good thermal conductivity, long service life, is easy to maintain, the heat efficiency above 75%.The  products can be widely used in telecom communication, power distribution, CNC machine, windmill etc automation Industry, for space cooling.

Working Principle

The outdoor cabinet/base station cooling heat exchanger was divided into operational ircle parts, they are isolated from

each other, in order to achieve water-proof and dustproof purposes.Two circles achieve the heat exchange in heat 

exchanger core.

Outer circle: The cold outdoor air enter into the heat exchanger from #1 air inlet, through the heat exchanger core, recover the heat from inter cycle, and expel from #2 air outlet.

Inter circle: The cabinet/base station internal temperature were rise up because of the electron components working, the hot air enter into the heat exchanger from #3 air inlet, transfer the heat to cold outdoor air, and expel from #4 air outlet, then draw back into the cabinet and base station, so as to cool the electron components and equipment.

Technical parameter:

 

Parameter

Unit

HEU C060

HEU C080

HEU

C100

HEU

C120

HEU C150

HEU

C180

Cooling Capacity

W/K

60

80

100

120

150

180

Air volume

m3//h

300

400

500

600

750

900

Static Pressure

Pa

Greater than 100

Power

W  DC-48V

75

115

157

220

220

240

W  AC-220V

 Optional Optional Optional

 Optional

 Optional

 Optional

Voltage

V

DC 48V       AC 220V

Temperature range

°C

-40 to 70 °C      0 to 100% RH

Noise

Db(A)

<60

<60

<60

<60

<60

<60

Demension

mm

1000*380*1381050*435*1581200*440*1881350*480*2181350*520*228

1420*520*248

Weight

Kg

22

26

31

38

43

48

Protection Grade

≥ IP54

         

Remark: Except standard products, we can also OME other size base on your request.