Base station air cooled exchanger for computer room

Base station air cooled exchanger for computer room
Product Detailed
1.Base station heat exchanger 2.Cooling capacity:1200W/k 3.Air volume:6000m3/h 4.CE and RoHs certification

Base station air cooled exchanger for computer room

Introduction:

HEU-S Series Base Station cabinet air exchaner system is specially design for mobile, telecom stations or computer room, etc, mainly used to eliminate the heat in the base station. The outdoor cold air after the purification, directly introduce into the equipment, then exchange the heat with exhaust air through the sensible heat recovery unit, expel heat from the equipment.

So as to cool the equipment, reduce the consumption of energy, and not only provide an ideal temperature and humidity environment for the cabinet air exchanger system, but also separate the dust and moisture from the equipment, greatly extend the service life of electronics parts and improve the system reliability.

Feature:

1.Energy Saving

It real-time control monitoring the inside and outside temperature ,when the outside temperature is lower to a certain extent, the equipment will begin to work, remove the inside heat to outside, so as to reduce the air-conditioner working time and save the energy.

2.Water And Dust Proof

Enclosed air circuit cooling system , completely isolate the inside and outside air, effectively avoid air contamination from outside.

Several Working Models and Standard RS485/RS232 Intelligent Control

3.DDGK function:

Setting the parameter for automatic protection, when the unit power outage, computer can record the parameter and outage information, after the power on, it will work again follow the status before the power outage ,it have the time delay function, to avoid power flash affect the unit or automatic trip .4.Air-conditioner Troubleshooting

When base station air conditioner goes wrong,the equipment remove the inner heat to outside in time, make sure the electron devices working well.

5.Protection Warning Function and Stable performance

High quality accessories and less moving parts, so as to reduce the machine fault and easy to maintenance.

Workflow of ERC heat exchanger core:

Aluminum foil core:

Performance Parameter:

Product Model (Large-size)

Parameter

Unit

HEU-S600

HEU-S800

HEU-S1000

HEU-S1200

Cooling capacity

W/K

600

800

1000

1200

Air Volume

M3/h

3000

4000

5000

6000

Static pressure

Pa

>50

100

Power

W

814

1760

1760

2420

Voltage

V

AC:380V

Temp. Range

°C

-40 to 70°C  0-100%RH

Noise

dB(A)

<65

Dimension

mm

1800x1400x605

2000x1680x625

2000x1680x725

2000x1680x825

Weight

Kg

86

102

132

168